Pilot #001 DemoAI Construction Plan-Check & Walkthrough Companion · Demo Case #001
Stage 0 Pre-Build Plan Audit
Cross-check architectural drawings, builder quote, TMK footing report, and HIA contract against NCC 2022 rules before slab pour.
Escalate to Licensed Inspector
PAYMENT-GATEDDispatch a certified building inspector to Sample New Build — Northern Adelaide SA armed with your 1-Page Co-Pilot Pre-Brief (4 Red action items & N2 truss tie-down map).
Marketplace Split: $400 AUD to Inspector · $100 AUD Scan My Build Co-Pilot Brief
Pilot Case #001 Inspections (2)
- Red
Pilot Case #001 — Stage 3 Frame & Truss Audit (Demo Case #001 — Pickard / Pryda Sheets 1–3)
Sample New Build — Northern Adelaide SA
25 Oct 2026 · 13 findings
Carries forward to Stage 4 photo checklist: 5 Red · 3 Amber
Open guided photo capture checklist →View 13 NCC & engineering findings
- defect-1 · framingRed
[FP-RED-01] Missing 90x35 MGP 10 B/C Brace Runners & Top-Chord Speedbrace on Trusses T1–T14 (Photos 12, 13, 14): Pickard Timber Sheets 2 & 3 mandate continuous 90x35 MGP 10 @ 1800mm c/c max (B/C brace - hanger) across bottom chords of T1–T15 and T19–T9, plus 4 diagonal steel Speedbrace runs across top chords. Rear/central trusses T1–T14 over Family/Meals lack both continuous bottom-chord runner ties and eastern/southern top-chord Speedbraces. Must be fitted prior to roof sheeting and ceiling battens.
Ref: NCC 2022 Vol 2 H1D6 / AS 4440 / Pickard Timber Pryda Sheets 2 & 3
- defect-2 · framingRed
[FP-RED-02] Un-nailed 30x 1/SB083/30 Strapbrace (S) Truss Tie-Downs Along Southern & Front Walls (Photos 01, 04, 05, 06, 07): Pickard Sheet 3 specifies 30 x 1/SB083/30 Strapbrace (S) at external supports of T1–T11 and T19–T9 for N2 (33m/s) wind compliance. Multiple straps along the Southern Elevation top plate and front garage PB 360x63 LVL are looped over trusses with tails bent outward and hanging un-nailed. Tension and fully nail off before roof loads.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2 / Pickard Timber Sheet 3 Connections (N2 Wind 33m/s)
- defect-3 · structuralRed
[FP-RED-03] Deep 45–60mm x 300mm Rectangular Notch in Internal Doorway Jamb Stud on Critical Load Path (Photos 16, 20): Pickard Sheet 1 carpenter notes strictly state 'JAMB STUDS (not to be notched)' and prohibit notching 90x45 MGP 10 internal point studs supporting the 12,550mm span trusses (T1–T14). Right-hand internal doorway jamb stud has a ~55mm deep x 300mm high cutout below mid-height nogging. Sister/laminate with full-height MGP 10 stud or replace prior to lining.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2 / Pickard Timber Sheet 1 Carpenter Notes
- defect-4 · structuralRed
[FP-RED-04] Garage 5410mm Opening PB 360x63 LVL Intermittent Top-Plate Packing & Propping Directive (Photos 01, 11): Pickard Sheet 1 mandates 'Prop beam until brickwork complete' and max 35mm truss load-transfer offset. Across the 5410mm garage opening, the 25–35mm gap between the PB 360x63 LVL and 2720mm top plate is packed with only 8 spaced timber blocks (leaving truss nodes unsupported >35mm from packers) and the upper top plate stops short of the northern corner stud cluster. Fit solid blocking under all truss nodes and retain central prop until brickwork cures.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2 / Pickard Timber Sheet 1 (35mm Offset & Propping Rule)
- defect-5 · framingRed
[AMBER-03] Missing Central Jack / Cripple Studs Above Internal Doorway Heads >600mm (Photos 16, 19, 20): Multiple internal partition doorway openings (~820–870mm wide) have a flat timber door head rail with an open span to the top plate and no central jack stud. AS/NZS 2589 requires vertical stud support at max 600mm centres above door heads to prevent gyprock corner cracking.
Ref: NCC 2022 Vol 2 H1D6 / AS/NZS 2589 (Gypsum Linings) / AS 1684.2
- defect-6 · otherAmber
[AMBER-04] Uncapped PVC Stormwater Risers Next to Bricklayer Pallets Around Slab Perimeter (Photos 03, 05, 07, 13): Multiple white PVC stormwater downpipe risers along the Southern Elevation and eastern slab perimeter have open tops with loose caps lying in the soil adjacent to delivered brick stacks. Cap or tape immediately before bricklayers mix mortar.
Ref: NCC 2022 Vol 2 H2D2 / AS/NZS 3500.3 / TMK Drainage Plan CRD
- defect-7 · framingAmber
[FP-AMBER-05] Twin 2/UT Unitie (V) Spine-Wall Check & Mannix Air A/C Truss Zone T8–T14 (Photos 14, 16, 20): Pickard Sheet 3 specifies 6 x 2/UT Unitie (double brackets marked V on T1, T5, T10 [x2], T14, T9) along the central spine wall and restricts indoor A/C fan coil dead load strictly to trusses T8, T7, and T14. Verify second UT bracket is fitted at all 6 V crossings and confirm A/C mounting zone before rough-in.
Ref: AS 4440 / Pickard Timber Pryda Sheets 2 & 3 (Internal Support V & A/C Unit Load)
- defect-8 · framingAmber
[FP-AMBER-06] Pre-Lining Check — Wet-Area Grab Rail Noggings (NCC 2022 Clause 6.2), Fascia Bracket 3-Screw Fixings & Northern Boundary Box-Flashing (Photos 05, 10, 20): Double-row vanity noggings are installed in the wet areas and grey fibre-cement cladding + top box-flashing are fitted on the northern boundary garage stud wall (Photo 10). Prior to VillaBoard and eave lining, confirm continuous 700–1000mm AFL grab-rail noggings around both showers/WCs and min 3 screws per metal fascia bracket.
Ref: NCC 2022 Livable Housing Design Standard Clause 6.2 / Architectural Sheets 01 & 07
- defect-9 · framingGreen
[GREEN-01] Verified Revision A Front Facade Windows (BTQMT 1821C + BTQMT 1806C) & 75x75x3.0 SHS Steel Portal (Photos 02, 03, 18): Post-contract Revision A changes (22/01/2026) are accurately framed with the wide Bed 1 opening and narrow Robe opening, supported by three primed 75x75x3.0 SHS steel posts and horizontal steel PFC lintel bolted to the slab.
Ref: Architectural Sheet 01–04 (Rev A 22/01/2026) & Pickard Timber Sheet 1
- defect-10 · structuralGreen
[GREEN-02] Verified N2 Structural Shear Bracing — OSB Type P Panels (P1–P4), Type D/S Tension Straps & Mechanical Slab Anchors (Photos 03, 07, 08, 12, 14, 18): Direction 1 (65.70 kN >= 47.25 kN req'd) and Direction 2 (74.70 kN >= 31.29 kN req'd) OSB shear walls, diagonal metal X cross-braces, (b)/(k) top-of-wall shear transfers (AS 1684.2 Table 8.22), and bottom-plate concrete screw-bolt anchors match Pickard Sheet 1.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2-2021 Table 8.22 / Pickard Timber Sheet 1 Bracing (P, D, S)
- defect-11 · structuralGreen
[GREEN-03] Verified Rear Verandah 90x90x2.0 DuraPost, PB 300x63 LVL Pitching Beams & SMART LVL 15 Slider Lintel (Photos 12, 13, 15): Rear Verandah corner DuraPost is bolted to the slab supporting PB 300x63 LVL perimeter beams, and the 2500mm Family/Meals sliding door (SD 2125) is spanned by a deep SMART LVL 15 lintel on 3/90x45 LVL jamb studs with vertical multigrip strap fixings.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2 / Pickard Timber Sheet 1 Lintel & Jamb Schedule
- defect-12 · framingGreen
[GREEN-04] Verified 2720mm Frame Plumb, Single-Row Nogging Spacing (<=1350mm c/c) & 870 CSD Cavity Slider Pocket Frames (Photos 05, 09, 17, 20): Wall frames are plumb within 2mm over 2.7m (max 4mm tolerance), metal-reinforced 870 CSD and 2/820 CSD cavity sliding door frames are square with transit braces intact, and double-row vanity blocking is fitted.
Ref: NCC 2022 Vol 2 H1D6 / AS 1684.2 / Pickard Timber Sheet 1
- defect-13 · slabGreen
[GREEN-05] Verified Slab Edge Rebate, 25mm Garage Recess, Blue Polyethylene DPM & 'Volume Builder Sample Lot' Truss Markings (Photos 01, 03, 12, 16): Perimeter brick rebate and 25mm garage step-down match TMK Footing Plan CR3 with zero boundary overpour, continuous blue DPM is installed beneath external bottom plates, and trusses are stamped 'Builder Lot Ref / Northern Adelaide'.
Ref: NCC 2022 Vol 2 H1D3 / AS 2870
IMPORTANT NOTICE — AUTOMATED AI SCREENING ONLY: This report was generated automatically from user-submitted photos by Scan My Build (Unaustralian Pty Ltd, ABN 65 703 953 691). It is for general guidance only and is not a statutory building inspection, engineering sign-off, or certification of compliance with NCC 2022 or Australian Standards. AI photo review cannot detect concealed defects. Always engage a licensed building inspector or structural engineer before approving stage payments or raising formal defect notices.
- Red
Pilot Case #001 — Stage 0 Pre-Build Plan, Footing & Contract Audit (Demo Case #001)
Sample New Build — Northern Adelaide SA
24 Oct 2026 · 7 findings
6 traps caught — $49 audit value deliveredCarries forward to Stage 1 photo checklist: 2 Red · 4 Amber
View 7 NCC & engineering findings
- defect-1 · slabRed
[STAGE0-RED-01] Critical Pre-Slab Set-Downs, Boundary Stormwater Sleeve & 40mm Pipe Lagging (TMK Sheet CR3): Class H2-D, P(FILL) site (Ys = 67 mm) mandates (a) 60mm concrete step-downs (SD) at both Ensuite and Main Bathroom showers for NCC 2022 step-free entry (plus 40mm wet-area and 25mm Garage/Portico/Verandah/Alfresco set-downs), (b) cast-in PVC stormwater sleeve through the northern boundary garage footing beams, and (c) 40mm closed-cell polyethylene lagging (not 20mm) with dual Denso-wrapped expansion couplings on all under-slab plumbing penetrations.
Ref: NCC 2022 Vol 2 H1D3 / AS 2870 / Livable Housing Clause 3.2 / TMK Sheet CR3
- defect-2 · slabRed
[STAGE0-RED-02] Deep Controlled Fill Up to 750mm Over Reinstated Stormwater Basin (LAB+Field PR-23/0420 C & TMK CR3): Borehole 2 (600mm) and Borehole 3 (750mm) exceed 400mm controlled fill. Northern boundary M-beam must be trenched >=600mm below existing ground or >=200mm into natural ground with 300mm slab thickening (SL72 Top & Bottom). Any uncertified fill >400mm requires upgrading main slab from 100mm to 120mm with dual SL72 mesh (CR3 Note 6).
Ref: NCC 2022 Vol 2 H1D3 / AS 2870 / Geotechnical Report & TMK Sheet CR3 Notes 1 & 6
- defect-3 · otherAmber
[STAGE0-AMBER-01] Kitchen Island Bench Electrical Feed Conflict (Demo Case #001 Quote p. 3 vs. Sheet 06): 'Island bench - (conduit for electrical) under slab' is marked Not Included, yet Dishwasher (DWP) and Under-Bench Microwave (MW PROV, $519 upgrade) are inside the 2460x900mm island. Because the island abuts eastern external wall under window SW 1221 ('BENCHTOP INTO WINDOW'), ensure 3 separate electrical feeds (DWP, MW, GPO) are roughed into the SW 1221 wall cavity at Frame/Pre-Plaster stage.
Ref: Stage 0 Plan-to-Quote Cross-Check / AS/NZS 3000
- defect-4 · finishesAmber
[STAGE0-AMBER-02] Main Bathroom Shower Niche Omission vs. Ensuite Tiled Shelf (Demo Case #001 Quote pp. 4–5 & Sheet 07): Ensuite includes a 90mm D tiled shelf recess at 1150 AFL ($600), but Main Bathroom 'Tiling - (niche recess) 415H x 415W x 90D, set 1250 AFL' is marked Not Included and omitted from Sheet 07. Confirm whether a niche should be framed before wall linings go up.
Ref: Stage 0 Plan-to-Selection Cross-Check / Sheet 03 & Sheet 07
- defect-5 · structuralAmber
[STAGE0-AMBER-03] Boundary Retaining Walls (200mm–400mm SRW) & Stormwater Excluded From Contract (Drainage Plan CRD & Annexure A Item I): Engineering requires 200mm–400mm Concrete Sleeper Retaining Walls along the Southern Elevation and eastern boundaries, but Quote pp. 1, 7 and Annexure A pp. 23, 27 assign all retaining walls, stormwater, paving, and boundary pegging strictly to the Owner.
Ref: Stage 0 HIA Contract Annexure A Item I & Drainage Plan CRD
- defect-6 · otherAmber
[STAGE0-AMBER-04] HIA Annexure A Page 25 '$650.00 Independent Expert Variation Fee' Trap: Contract Clause 13 / Annexure A imposes a $650.00 (inc. GST) builder variation fee per stage if the Owner brings an external Independent Expert onto the site prior to Practical Completion. Using Scan My Build's guided supervisor walkthrough capture avoids this $650/stage penalty.
Ref: HIA Building Contract Clause 13 & Annexure A Page 25 ('Appointment of Expert')
- defect-7 · otherGreen
[STAGE0-GREEN-01] Promotional Designer Basin Quota Cap Verified (Demo Case #001 Quote pp. 4–5 & Sheet 07): 3-basin house (Ensuite 1800mm twin vanity + Bathroom 1950mm single vanity) is correctly priced. Promotional package caps Seima Kyra 400 basins + Pina mixers at 2 units; the 3rd Ensuite basin legitimately requires both the extra basin cabinetry provision and the designer specification upgrade delta ($225 + $97).
Ref: Stage 0 Builder Commercial Pricing Rule — Promotional Quota Cap
IMPORTANT NOTICE — AUTOMATED AI SCREENING ONLY: This report was generated automatically from user-submitted photos by Scan My Build (Unaustralian Pty Ltd, ABN 65 703 953 691). It is for general guidance only and is not a statutory building inspection, engineering sign-off, or certification of compliance with NCC 2022 or Australian Standards. AI photo review cannot detect concealed defects. Always engage a licensed building inspector or structural engineer before approving stage payments or raising formal defect notices.